{"id":577,"date":"2018-04-27T02:14:09","date_gmt":"2018-04-26T23:14:09","guid":{"rendered":"http:\/\/ardcon.kz\/?page_id=577"},"modified":"2024-03-14T17:12:04","modified_gmt":"2024-03-14T12:12:04","slug":"izmerenie-tolshhiny-pokrytiya-metalla","status":"publish","type":"page","link":"https:\/\/ardcon.kz\/en\/izmerenie-tolshhiny-pokrytiya-metalla\/","title":{"rendered":"Measuring the thickness of the metal coating"},"content":{"rendered":"<p><\/p>\n<p>Magnetic coating thickness gauge MT-2007&nbsp;is designed to&nbsp;measure thickness of&nbsp;paint and lacquer, electroplating, fire-retardant, and any other non-magnetic current conducting and non-conducting coatings on&nbsp;ferromagnetic (steel, cast iron etc.) foundations. <\/p>\n<h2>Main features<\/h2>\n<ul>\n<li>Thickness measurement of&nbsp;coating on&nbsp;magnetic foundation in&nbsp;a&nbsp;wide range of&nbsp;two to&nbsp;30&nbsp;000&nbsp;micrometers.<\/li>\n<li>Measurement of&nbsp;rust thickness on&nbsp;steel, including that on&nbsp;inner pipe walls (using special-purpose transducers).<\/li>\n<li>Thickness measurement of&nbsp;electroplated (zinc, chrome, cadmium, silver and other) coatings on&nbsp;magnetic foundations (steel etc.).<\/li>\n<li>Performance both local (in&nbsp;a&nbsp;given location) and continuous measurements (scanning mode), in&nbsp;which case an&nbsp;operator can evaluate coating spreading on&nbsp;metal directly in&nbsp;each scanning point.<\/li>\n<li>The function of&nbsp;arithmetical average and mean-square deviation evaluation, in&nbsp;which case an&nbsp;operator is&nbsp;only required to&nbsp;measure a&nbsp;minimum in&nbsp;three points to&nbsp;estimate coating uniformity.<\/li>\n<li>Indicator image of&nbsp;a&nbsp;minimum and a&nbsp;maximum among measured values.<\/li>\n<li>Possible connection of&nbsp;up&nbsp;to&nbsp;seven types of&nbsp;different measurement range transducers to&nbsp;one electronic unit, designed to&nbsp;solve different problems, such as&nbsp;measurements in&nbsp;hard-to-reach places, thickness measurements of&nbsp;coatings on&nbsp;parts with small curve radius etc.<\/li>\n<li>Non-volatile memory.<\/li>\n<li>PC&nbsp;connection (optional).<\/li>\n<li>Automatic trip on&nbsp;operation pause.<\/li>\n<li>Spring-loaded transducers pin and <nobr>V-opening<\/nobr> provide reliable contact of&nbsp;a&nbsp;transducer with check coating surface and high frequency of&nbsp;measurement of&nbsp;curved objects.<\/li>\n<\/ul>\n<h2><strong>Potential uses<\/strong><\/h2>\n<ul>\n<li>Oil and gas industry<\/li>\n<li>Chemical and food-processing industries<\/li>\n<li>Ship building and repairing<\/li>\n<li>Thermal and nuclear power industry<\/li>\n<li>Pipe rolling, machine-building and transportation enterprises<\/li>\n<li>Municipal public services<\/li>\n<\/ul>\n<p><strong>LLP \u201cARDCON\u201d offers services of&nbsp;welding and metal testing laboratory. The laboratory is&nbsp;certified to&nbsp;the following control methods: radiographic testing, ultrasonic flaw detection, ultrasonic thickness measurement, metal hardness measurement, liquid penetrant testing, magnetic particle inspection and other NDT methods. For consultation, a&nbsp;potential customer can contact with our technical specialists and discuss the questions.<\/strong><\/p>\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Magnetic coating thickness gauge MT-2007&nbsp;is designed to&nbsp;measure thickness of&nbsp;paint and lacquer, electroplating, fire-retardant, and any other non-magnetic current conducting and non-conducting coatings on&nbsp;ferromagnetic (steel, cast iron etc.) foundations. Main features Thickness measurement of&nbsp;coating on&nbsp;magnetic foundation in&nbsp;a&nbsp;wide range of&nbsp;two to&nbsp;30&nbsp;000&nbsp;micrometers. Measurement of&nbsp;rust thickness on&nbsp;steel, including that on&nbsp;inner pipe walls (using special-purpose transducers). Thickness measurement of&nbsp;electroplated (zinc, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-577","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/ardcon.kz\/en\/wp-json\/wp\/v2\/pages\/577","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ardcon.kz\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ardcon.kz\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ardcon.kz\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ardcon.kz\/en\/wp-json\/wp\/v2\/comments?post=577"}],"version-history":[{"count":1,"href":"https:\/\/ardcon.kz\/en\/wp-json\/wp\/v2\/pages\/577\/revisions"}],"predecessor-version":[{"id":4710,"href":"https:\/\/ardcon.kz\/en\/wp-json\/wp\/v2\/pages\/577\/revisions\/4710"}],"wp:attachment":[{"href":"https:\/\/ardcon.kz\/en\/wp-json\/wp\/v2\/media?parent=577"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}